Manufacturer: V&F
V&F TwinSense
Dual IMR-MS analyzer for fast, simultaneous measurements upstream and downstream of a catalytic converter.
Key features
- Two IMR-MS units for simultaneous pre- and post-catalyst measurement
- Analysis time 10 ms and response time T90 < 150 ms per channel
- Mass range 7–519 amu on both channels
- Heated gas inlets adjustable from 50 to 190 °C
Technical data
- Measuring principle
- Dual ion-molecule reaction mass spectrometry (2 x IMR-MS)
- Mass range
- 7–519 amu (each IMR-MS)
- Resolution
- < 1 amu
- Analysis time
- 10 ms
- Measuring range
- 10^5
- Response time
- T90 < 150 ms
- Detection limit
- 100 ppb
- Concentration drift
- < ±5 % over 24 h
- Accuracy
- < ±3 %
- Precision
- < ±3 %
- Ambient temperature
- 20–35 °C
- Max. humidity
- 80 % (non-condensing)
- Gas consumption
- 30–3000 ml/min (each IMR-MS)
- Gas inlet temperature
- 50–190 °C, adjustable
- Gas inlet pressure
- 0.75–2 bar(a)
- Power supply
- 230 V/50 Hz or 115 V/60 Hz, 1250 W (each IMR-MS)
- Dimensions (W x H x D)
- 600 x 1692 x 700 mm
- Weight
- 208 kg
Description
The V&F TwinSense houses two ion-molecule reaction mass spectrometers (IMR-MS) in one analyzer. The dual configuration is designed for fast, simultaneous measurements before and after the catalytic converter.
Typical applications
- Development of internal combustion engines (diesel and petrol)
- Rapid measurement of hydrocarbons
- Ammonia measurements on DeNOx catalysts
- NOx measurements on diesel engines
- Alternative fuels
- Catalyst development
- Desulfurisation measures
Application examples
Automotive industry
- Ammonia and NOx measurements in engine exhaust gas
- Desulfation strategies for catalytic converters
Measurable compounds
- Inorganic compounds: H2O, O2, CO2, CO, H2S, SO2, S, NH3, NO, NO2, N2O, HCl
- Aromatics: C6H6 (benzene), C7H8 (toluene), C8H8 (styrene), C8H10 (xylene/ethylbenzene), C6H6O (phenol), PAHs
- Alkanes: CH4, C2H6, C3H8, C4H10, C5H12, C6H14, C7H16, C8H18, C9H20, C10H22
- Alkynes: C2H2 (acetylene), C3H4 (propyne)
- Sulfur compounds: H2S, COS, SO2, CS2, CH3SH, C2H5SH
- Nitrogen compounds: NH3, NO, NO2, N2O
- Alcohols: CH3OH, C2H5OH, C3H7OH, C4H9OH
- Aldehydes: HCHO (formaldehyde), CH3CHO (acetaldehyde), C2H5CHO (propionaldehyde), C6H12O (hexanal), C7H6O (benzaldehyde)
Values marked as application-dependent (measuring range, response time, detection limit, gas consumption) depend on the compounds measured, the system configuration and the instrument settings.
Ask about this machine
Send us your question or the details of your project. We usually reply within one working day.
More in this range

V&F AirSense
Multi-purpose IMR-MS mass spectrometer for an unlimited number of gas components, built for flexibility and robustness across automotive, food, environmental and medical applications.
V&F
V&F CO2Sense
IMR-MS analyzer developed for measuring organic and inorganic impurities in CO2, meeting common food and beverage CO2 quality specifications such as ISBT and EIGA.
V&F
V&F PETSense
IMR-MS sniffer for the fast, accurate detection of contaminated refillable PET bottles, installed in a master inspection system (supplied as OEM via Krones as Aircontronic).