V&F CO2Sense

IMR-MS analyzer developed for measuring organic and inorganic impurities in CO2, meeting common food and beverage CO2 quality specifications such as ISBT and EIGA.

Key features

  • Designed for CO2 purity to ISBT and EIGA specifications
  • Measures organic and inorganic impurities in one analyzer
  • Dual gas inlet for product gas and raw gas
  • Detection limit 100 ppt

Technical data

Measuring principle
Ion-molecule reaction mass spectrometry (IMR-MS)
Mass range
7–519 amu
Resolution
< 1 amu
Analysis time
>= 100 ms
Measuring range
10^5
Response time
T90 < 150 ms
Detection limit
100 ppt
Concentration drift
< ±5 % over 24 h
Accuracy
< ±3 %
Precision
< ±3 %
Ambient temperature
20–35 °C
Max. humidity
80 % (non-condensing)
Gas consumption
1000–2000 ml
Gas inlet temperature (product gas)
unheated
Gas inlet temperature (raw gas)
110 °C
Gas inlet pressure
1–2 bar(a)
Power supply
230 V/50 Hz or 115 V/60 Hz, 800 W
Dimensions (W x H x D)
534 x 743 x 639 mm
Weight
75 / 87 kg

Description

The V&F CO2Sense uses an ion-molecule reaction mass spectrometer (IMR-MS) and was developed specifically to measure organic and inorganic impurities in carbon dioxide. With it, the common CO2 quality specifications of the food and beverage industry, such as ISBT and EIGA, can be met.

The analyzer has a dual gas inlet: an unheated inlet for the product gas and a heated inlet (110 °C) for raw gas.

Typical applications

  • Final CO2 quality control – measurement of organic and inorganic impurities in CO2
  • Monitoring of impurities in CO2 raw and process gas

Application examples

Food and beverage industries

  • Quality control of CO2 for the food and beverage sector

Gas industry

  • Feed gas and process monitoring in CO2 production

Specialty and industrial gases

  • CO2 raw gas measurement and process control

Measurable compounds

  • ISBT compounds: O2, NH3, NO, NO2, CH3OH (methanol), total volatile hydrocarbons (THC), CH4, C2H4O (acetaldehyde), aromatic hydrocarbons, C6H6, C7H8, C8H10 (xylene), total sulfur (TSC), COS, H2S, CS2, CH3SH, SO2, C2H5SH, C2H6S2 (dimethyl disulfide), HCN, C2H3Cl (vinyl chloride), PH3
  • Non-ISBT compounds: C3H6O (propanal, acetone), C2H5OH, C4H8O2 (ethyl acetate), C2H4O2 (methyl formate), C3H6O2 (ethyl formate), C6H12O2 (tert-butyl acetate), C5H12O (isoamyl alcohol), C4H10O (isobutyl alcohol), C3H8O (2-propanol), C2H4, C3H6, C4H6, C2H2, C2H6, CHCl3, C2H4Cl2, C2HCl3, C2H2Cl4, CH2BrCl, CHBr2Cl, CHBr3